{"id":6458,"date":"2025-07-19T02:32:35","date_gmt":"2025-07-18T19:32:35","guid":{"rendered":"https:\/\/rothwell.co.th\/?page_id=6458"},"modified":"2025-07-19T04:59:04","modified_gmt":"2025-07-18T21:59:04","slug":"ac-series-class-ii-a2-biological-safety-cabinet","status":"publish","type":"page","link":"https:\/\/rothwell.co.th\/index.php\/ac-series-class-ii-a2-biological-safety-cabinet\/","title":{"rendered":"AC Series Class II A2 Biological Safety Cabinet"},"content":{"rendered":"\n<p style=\"font-size:24px\">AC Series Class II A2 Biological Safety Cabinet <\/p>\n\n\n\n<p style=\"font-size:24px\">Model:BSC-1100\u2161A2-X BSC-1300\u2161A2-X BSC-1500\u2161A2-X BSC-1800\u2161A2-X BSC-2000\u2161A2-X<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"wp-block-image\">\n<figure class=\"alignright size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"287\" height=\"477\" src=\"https:\/\/rothwell.co.th\/wp-content\/uploads\/2025\/07\/bsc-1100-ii-a2-x-main-copy.webp\" alt=\"\" class=\"wp-image-6460\" srcset=\"https:\/\/rothwell.co.th\/wp-content\/uploads\/2025\/07\/bsc-1100-ii-a2-x-main-copy.webp 287w, https:\/\/rothwell.co.th\/wp-content\/uploads\/2025\/07\/bsc-1100-ii-a2-x-main-copy-181x300.webp 181w\" sizes=\"(max-width: 287px) 100vw, 287px\" \/><\/figure>\n<\/div>\n\n\n<div style=\"height:43px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-blue-color has-text-color has-link-color wp-elements-a659ea34a33d69777d0545708a3377fa\"><a href=\"https:\/\/rothwell.co.th\/index.php\/mf-pro-series-class-ll-a2-biological-safety-cabinet\/\">Pro Series Class II A2 Biological Safety Cabinet<\/a><\/li>\n\n\n\n<li class=\"has-blue-color has-text-color has-link-color wp-elements-1c445cd872c75cab9ab7c25dc42f1c44\"><a href=\"https:\/\/rothwell.co.th\/index.php\/basic-series-class-ii-a2-biological-safety-cabinet\/\">Basic Series Class II A2 Biological Safety Cabinet<\/a><\/li>\n\n\n\n<li class=\"has-blue-color has-text-color has-link-color wp-elements-922558370e18295179fa92eea7ef64fd\"><a href=\"https:\/\/rothwell.co.th\/index.php\/basic-series-class-ii-a2-biological-safety-cabinet\/\">AC Series Class II A2 Biological Safety Cabinet<\/a><\/li>\n\n\n\n<li class=\"has-blue-color has-text-color has-link-color wp-elements-e15443fe1791d145e0e049c8733f8527\"><\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<h2 class=\"wp-block-heading\">ADVANTAGE<\/h2>\n\n\n\n<p><strong>AC Series Class II A2 Biological Safety Cabinet\u00a0<\/strong><\/p>\n\n\n\n<p><strong>Introduction:<\/strong><\/p>\n\n\n\n<p>Biosafety cabinet is a box-type air purification negative pressure safety device that can prevent the aerosol escape of some dangerous or unknown biological particles in the process of experimental operation. It is widely used in scientific research, teaching, clinical testing and production in the fields of microbiology, genetic engineering and biological products, and is the most basic safety protection equipment in the first-level protective barrier of laboratory biosafety.<\/p>\n\n\n\n<p><strong>Features:<\/strong><\/p>\n\n\n\n<p>1. Color key display: large screen, more clear and dynamic display of various values of the safety cabinet, and has the function of appointment timing.                                                                   2. Automatically adjust the wind speed.                                                                                                3. With power-off memory function, the state before power-off will be restored after power-on, and there will be visual prompts and alarms.                                                                              4. The integrated design of the operation area makes it easy to disassemble and clean.              5. The cabinet is separated from the base. The height of the adjustable base can be customized.             6. Interlocking function: UV lamp and front window; UV lamp and fan, LED lamp; fan and front window.                                                                                                                                                   7. It has the function of appointment timing, which can automatically set the time of starting and shutting down the safety cabinet and the running time of ultraviolet lamps, fans and sockets.           8. The front window closes the double trigger signal, so that the sterilization and disinfection function of the ultraviolet lamp is normally turned on.                                                                                      9. The negative pressure air duct is equipped with a foreign matter filtering structure to prevent foreign matter such as paper scraps from entering the fan system and affecting the normal operation of the product.                                                                                                                       10. The front window glass has a one-key lift function                                                                      11. The cabinet is designed with a 10\u00b0 inclination angle, which is in line with ergonomic principles, with a larger viewing angle, convenient operation and more humanization.                    12. The one-piece hand rest has a large flat surface, which has a larger contact area with the arm and is more comfortable.<\/p>\n<\/div>\n<\/div>\n\n\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-6aabbf211af7410d5889a75118f4a274\" style=\"font-size:37px\">Technical Parameters<\/p>\n\n\n\n<p style=\"font-size:37px\"><strong>MODEL<\/strong> : <strong>BSC-1100IIA2-X<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\" style=\"font-size:16px\"><table class=\"has-brown-color has-text-color has-link-color has-fixed-layout\"><thead><tr><th><strong>MODEL <\/strong>   <\/th><th><strong>BSC-1100IIA2-X            <\/strong><\/th><\/tr><\/thead><tbody><tr><td> External Size(W<em>D<\/em>H)<\/td><td>1100*755*2200mm<\/td><\/tr><tr><td>Internal Size(W<em>D<\/em>H)<\/td><td>940*600*660mm<\/td><\/tr><tr><td>Tested Opening<\/td><td>Safety height 200mm(8&#8243;)<\/td><\/tr><tr><td>Max Opening<\/td><td>480mm<\/td><\/tr><tr><td>Inflow Velocity<\/td><td>0.53\u00b10.025m\/s<\/td><\/tr><tr><td>Down Flow Velocity<\/td><td>0.33\u00b10.025m\/s<\/td><\/tr><tr><td>HEPA Filter<\/td><td>Two, 99.9995% efficiency at 0.12\u03bcm, filter life indicator<\/td><\/tr><tr><td>Front Window<\/td><td>DMotorized. Two-layer laminated toughened glass\u22656mm. Anti UV<\/td><\/tr><tr><td>Noise<\/td><td>\u226465dB<\/td><\/tr><tr><td>UV Lamp<\/td><td>30W*1 <br>UV timer, UV life indicator, emission of 253.7 nanometers for most efficient decontamination<\/td><\/tr><tr><td>LED Lamp<\/td><td>12W *2<\/td><\/tr><tr><td>Illumination<\/td><td> \u22651000Lux<\/td><\/tr><tr><td>Consumption<\/td><td>600w<\/td><\/tr><tr><td>Socket<\/td><td> Two, total load of two sockets: 500W<\/td><\/tr><tr><td>Display<\/td><td>LCD display: exhaust filter and downflow filter pressure, filter and UV lamp working time, inflow and downflow velocity, filter life, humidity and temperature, system working time etc.<\/td><\/tr><tr><td>Control System<\/td><td>  Microprocessor<\/td><\/tr><tr><td>Airflow System<\/td><td> 70% air recirculation, 30% air exhaust<\/td><\/tr><tr><td>Visual and Audio Alarm<\/td><td>Abnormal airflow velocity, filter replacement, front window at unsafe height, high filter pressure alarm, abnormal power failure<\/td><\/tr><tr><td>Material<br><\/td><td>  Work Zone: 304 stainless steel<br>  Main Body: Cold-rolled steel with anti-bacteria powder coating<\/td><\/tr><tr><td>Work Surface Height<\/td><td>770mm(Can be customized)<\/td><\/tr><tr><td>Caster<\/td><td>Footmaster caster<\/td><\/tr><tr><td>Power Supply<\/td><td>AC220V, 50\/60Hz; 110V, 60Hz<\/td><\/tr><tr><td>Standard Accessory<\/td><td>LED lamp 2pcs(except for BSC-2000IIA2-X 4pcs), UV lamp 2pcs, Base stand, Remote control, Foot switch, Drain valve, Waterproof socket 2pcs<\/td><\/tr><tr><td>Optional Accessory<\/td><td>Water and gas tap, Electric height adjustable base stand, Armrest<\/td><\/tr><tr><td>Packing Size <\/td><td>1230*990*1840mm<\/td><\/tr><tr><td>Gross Weight <br>(without base stand)<\/td><td>220kg<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p style=\"font-size:37px\"><strong>MODEL<\/strong> : <strong>BSC-1300IIA2-X            <\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\" style=\"font-size:16px\"><table class=\"has-brown-color has-text-color has-link-color has-fixed-layout\"><thead><tr><th><strong>MODEL <\/strong>   <\/th><th><strong> BSC-1300IIA2-X           <\/strong><\/th><\/tr><\/thead><tbody><tr><td> External Size(W<em>D<\/em>H)<\/td><td>1300*755*2200mm<\/td><\/tr><tr><td>Internal Size(W<em>D<\/em>H)<\/td><td>1150*600*660mm<\/td><\/tr><tr><td>Tested Opening<\/td><td>Safety height 200mm(8&#8243;)<\/td><\/tr><tr><td>Max Opening<\/td><td>480mm<\/td><\/tr><tr><td>Inflow Velocity<\/td><td>0.53\u00b10.025m\/s<\/td><\/tr><tr><td>Down Flow Velocity<\/td><td>0.33\u00b10.025m\/s<\/td><\/tr><tr><td>HEPA Filter<\/td><td>Two, 99.9995% efficiency at 0.12\u03bcm, filter life indicator<\/td><\/tr><tr><td>Front Window<\/td><td>DMotorized. Two-layer laminated toughened glass\u22656mm. Anti UV<\/td><\/tr><tr><td>Noise<\/td><td>\u226465dB<\/td><\/tr><tr><td>UV Lamp<\/td><td>30W*1 <br>UV timer, UV life indicator, emission of 253.7 nanometers for most efficient decontamination<\/td><\/tr><tr><td>LED Lamp<\/td><td>14W *2<\/td><\/tr><tr><td>Illumination<\/td><td> \u22651000Lux<\/td><\/tr><tr><td>Consumption<\/td><td>800w<\/td><\/tr><tr><td>Socket<\/td><td> Two, total load of two sockets: 500W<\/td><\/tr><tr><td>Display<\/td><td>LCD display: exhaust filter and downflow filter pressure, filter and UV lamp working time, inflow and downflow velocity, filter life, humidity and temperature, system working time etc.<\/td><\/tr><tr><td>Control System<\/td><td>  Microprocessor<\/td><\/tr><tr><td>Airflow System<\/td><td> 70% air recirculation, 30% air exhaust<\/td><\/tr><tr><td>Visual and Audio Alarm<\/td><td>Abnormal airflow velocity, filter replacement, front window at unsafe height, high filter pressure alarm, abnormal power failure<\/td><\/tr><tr><td>Material<br><\/td><td>  Work Zone: 304 stainless steel<br>  Main Body: Cold-rolled steel with anti-bacteria powder coating<\/td><\/tr><tr><td>Work Surface Height<\/td><td>770mm(Can be customized)<\/td><\/tr><tr><td>Caster<\/td><td>Footmaster caster<\/td><\/tr><tr><td>Power Supply<\/td><td>AC220V, 50\/60Hz; 110V, 60Hz<\/td><\/tr><tr><td>Standard Accessory<\/td><td>LED lamp 2pcs(except for BSC-2000IIA2-X 4pcs), UV lamp 2pcs, Base stand, Remote control, Foot switch, Drain valve, Waterproof socket 2pcs<\/td><\/tr><tr><td>Optional Accessory<\/td><td>Water and gas tap, Electric height adjustable base stand, Armrest<\/td><\/tr><tr><td>Packing Size <\/td><td>1430*990*1840mm<\/td><\/tr><tr><td>Gross Weight <br>(without base stand)<\/td><td>280kg<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p style=\"font-size:37px\"><strong>MODEL<\/strong> : <strong>BSC-1500IIA2-X<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\" style=\"font-size:16px\"><table class=\"has-brown-color has-text-color has-link-color has-fixed-layout\"><thead><tr><th><strong>MODEL <\/strong>   <\/th><th><strong>BSC-1500IIA2-X<\/strong><\/th><\/tr><\/thead><tbody><tr><td> External Size(W<em>D<\/em>H)<\/td><td>1500*755*2200mm<\/td><\/tr><tr><td>Internal Size(W<em>D<\/em>H)<\/td><td>1350*600*660mm<\/td><\/tr><tr><td>Tested Opening<\/td><td>Safety height 200mm(8&#8243;)<\/td><\/tr><tr><td>Max Opening<\/td><td>480mm<\/td><\/tr><tr><td>Inflow Velocity<\/td><td>0.53\u00b10.025m\/s<\/td><\/tr><tr><td>Down Flow Velocity<\/td><td>0.33\u00b10.025m\/s<\/td><\/tr><tr><td>HEPA Filter<\/td><td>Two, 99.9995% efficiency at 0.12\u03bcm, filter life indicator<\/td><\/tr><tr><td>Front Window<\/td><td>DMotorized. Two-layer laminated toughened glass\u22656mm. Anti UV<\/td><\/tr><tr><td>Noise<\/td><td>\u226465dB<\/td><\/tr><tr><td>UV Lamp<\/td><td>40W*1 <br>UV timer, UV life indicator, emission of 253.7 nanometers for most efficient decontamination<\/td><\/tr><tr><td>LED Lamp<\/td><td>16W*2<\/td><\/tr><tr><td>Illumination<\/td><td> \u22651000Lux<\/td><\/tr><tr><td>Consumption<\/td><td>1300w<\/td><\/tr><tr><td>Socket<\/td><td> Two, total load of two sockets: 500W<\/td><\/tr><tr><td>Display<\/td><td>LCD display: exhaust filter and downflow filter pressure, filter and UV lamp working time, inflow and downflow velocity, filter life, humidity and temperature, system working time etc.<\/td><\/tr><tr><td>Control System<\/td><td>  Microprocessor<\/td><\/tr><tr><td>Airflow System<\/td><td> 70% air recirculation, 30% air exhaust<\/td><\/tr><tr><td>Visual and Audio Alarm<\/td><td>Abnormal airflow velocity, filter replacement, front window at unsafe height, high filter pressure alarm, abnormal power failure<\/td><\/tr><tr><td>Material<br><\/td><td>  Work Zone: 304 stainless steel<br>  Main Body: Cold-rolled steel with anti-bacteria powder coating<\/td><\/tr><tr><td>Work Surface Height<\/td><td>770mm(Can be customized)<\/td><\/tr><tr><td>Caster<\/td><td>Footmaster caster<\/td><\/tr><tr><td>Power Supply<\/td><td>AC220V, 50\/60Hz; 110V, 60Hz<\/td><\/tr><tr><td>Standard Accessory<\/td><td>LED lamp 2pcs(except for BSC-2000IIA2-X 4pcs), UV lamp 2pcs, Base stand, Remote control, Foot switch, Drain valve, Waterproof socket 2pcs<\/td><\/tr><tr><td>Optional Accessory<\/td><td>Water and gas tap, Electric height adjustable base stand, Armrest<\/td><\/tr><tr><td>Packing Size <\/td><td>1630*990*1840mm<\/td><\/tr><tr><td>Gross Weight <br>(without base stand)<\/td><td>316 kg<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p style=\"font-size:37px\"><strong>MODEL<\/strong> : <strong>BSC-1800IIA2-X<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\" style=\"font-size:16px\"><table class=\"has-brown-color has-text-color has-link-color has-fixed-layout\"><thead><tr><th><strong>MODEL <\/strong>   <\/th><th><strong>BSC-1800IIA2-X            <\/strong><\/th><\/tr><\/thead><tbody><tr><td> External Size(W<em>D<\/em>H)<\/td><td>1800*755*2200mm<\/td><\/tr><tr><td>Internal Size(W<em>D<\/em>H)<\/td><td>91625*600*660mm<\/td><\/tr><tr><td>Tested Opening<\/td><td>Safety height 200mm(8&#8243;)<\/td><\/tr><tr><td>Max Opening<\/td><td>480mm<\/td><\/tr><tr><td>Inflow Velocity<\/td><td>0.53\u00b10.025m\/s<\/td><\/tr><tr><td>Down Flow Velocity<\/td><td>0.33\u00b10.025m\/s<\/td><\/tr><tr><td>HEPA Filter<\/td><td>Two, 99.9995% efficiency at 0.12\u03bcm, filter life indicator<\/td><\/tr><tr><td>Front Window<\/td><td>DMotorized. Two-layer laminated toughened glass\u22656mm. Anti UV<\/td><\/tr><tr><td>Noise<\/td><td>\u226465dB<\/td><\/tr><tr><td>UV Lamp<\/td><td>40W*1<br>UV timer, UV life indicator, emission of 253.7 nanometers for most efficient decontamination<\/td><\/tr><tr><td>LED Lamp<\/td><td>16W *2<\/td><\/tr><tr><td>Illumination<\/td><td> \u22651000Lux<\/td><\/tr><tr><td>Consumption<\/td><td>1300w<\/td><\/tr><tr><td>Socket<\/td><td> Two, total load of two sockets: 500W<\/td><\/tr><tr><td>Display<\/td><td>LCD display: exhaust filter and downflow filter pressure, filter and UV lamp working time, inflow and downflow velocity, filter life, humidity and temperature, system working time etc.<\/td><\/tr><tr><td>Control System<\/td><td>  Microprocessor<\/td><\/tr><tr><td>Airflow System<\/td><td> 70% air recirculation, 30% air exhaust<\/td><\/tr><tr><td>Visual and Audio Alarm<\/td><td>Abnormal airflow velocity, filter replacement, front window at unsafe height, high filter pressure alarm, abnormal power failure<\/td><\/tr><tr><td>Material<br><\/td><td>  Work Zone: 304 stainless steel<br>  Main Body: Cold-rolled steel with anti-bacteria powder coating<\/td><\/tr><tr><td>Work Surface Height<\/td><td>800mm(Can be customized)<\/td><\/tr><tr><td>Caster<\/td><td>Footmaster caster<\/td><\/tr><tr><td>Power Supply<\/td><td>AC220V, 50\/60Hz; 110V, 60Hz<\/td><\/tr><tr><td>Standard Accessory<\/td><td>LED lamp 2pcs(except for BSC-2000IIA2-X 4pcs), UV lamp 2pcs, Base stand, Remote control, Foot switch, Drain valve, Waterproof socket 2pcs<\/td><\/tr><tr><td>Optional Accessory<\/td><td>Water and gas tap, Electric height adjustable base stand, Armrest<\/td><\/tr><tr><td>Packing Size <\/td><td>1930*990*1840mm<\/td><\/tr><tr><td>Gross Weight <br>(without base stand)<\/td><td>366 kg<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p style=\"font-size:37px\"><strong>MODEL<\/strong> : <strong>BSC-2000IIA2-X<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\" style=\"font-size:16px\"><table class=\"has-brown-color has-text-color has-link-color has-fixed-layout\"><thead><tr><th><strong>MODEL <\/strong>   <\/th><th><strong>BSC-2000IIA2-X            <\/strong><\/th><\/tr><\/thead><tbody><tr><td> External Size(W<em>D<\/em>H)<\/td><td>1950*775*2200mm<\/td><\/tr><tr><td>Internal Size(W<em>D<\/em>H)<\/td><td>1800*600*660mm<\/td><\/tr><tr><td>Tested Opening<\/td><td>Safety height 200mm(8&#8243;)<\/td><\/tr><tr><td>Max Opening<\/td><td>480mm<\/td><\/tr><tr><td>Inflow Velocity<\/td><td>0.53\u00b10.025m\/s<\/td><\/tr><tr><td>Down Flow Velocity<\/td><td>0.33\u00b10.025m\/s<\/td><\/tr><tr><td>HEPA Filter<\/td><td>Two, 99.9995% efficiency at 0.12\u03bcm, filter life indicator<\/td><\/tr><tr><td>Front Window<\/td><td>DMotorized. Two-layer laminated toughened glass\u22656mm. Anti UV<\/td><\/tr><tr><td>Noise<\/td><td>\u226465dB<\/td><\/tr><tr><td>UV Lamp<\/td><td>40W*1<br>UV timer, UV life indicator, emission of 253.7 nanometers for most efficient decontamination<\/td><\/tr><tr><td>LED Lamp<\/td><td>12W *2<\/td><\/tr><tr><td>Illumination<\/td><td> \u22651000Lux<\/td><\/tr><tr><td>Consumption<\/td><td>1700W<\/td><\/tr><tr><td>Socket<\/td><td> Two, total load of two sockets: 500W<\/td><\/tr><tr><td>Display<\/td><td>LCD display: exhaust filter and downflow filter pressure, filter and UV lamp working time, inflow and downflow velocity, filter life, humidity and temperature, system working time etc.<\/td><\/tr><tr><td>Control System<\/td><td>  Microprocessor<\/td><\/tr><tr><td>Airflow System<\/td><td> 70% air recirculation, 30% air exhaust<\/td><\/tr><tr><td>Visual and Audio Alarm<\/td><td>Abnormal airflow velocity, filter replacement, front window at unsafe height, high filter pressure alarm, abnormal power failure<\/td><\/tr><tr><td>Material<br><\/td><td>  Work Zone: 304 stainless steel<br>  Main Body: Cold-rolled steel with anti-bacteria powder coating<\/td><\/tr><tr><td>Work Surface Height<\/td><td><br>800mm(Can be customized)<\/td><\/tr><tr><td>Caster<\/td><td>Footmaster caster<\/td><\/tr><tr><td>Power Supply<\/td><td>AC220V, 50\/60Hz; 110V, 60Hz<\/td><\/tr><tr><td>Standard Accessory<\/td><td>LED lamp 2pcs(except for BSC-2000IIA2-X 4pcs), UV lamp 2pcs, Base stand, Remote control, Foot switch, Drain valve, Waterproof socket 2pcs<\/td><\/tr><tr><td>Optional Accessory<\/td><td>Water and gas tap, Electric height adjustable base stand, Armrest<\/td><\/tr><tr><td>Packing Size <\/td><td>2080*990*1840mm<\/td><\/tr><tr><td>Gross Weight <br>(without base stand)<\/td><td>420kg<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div class=\"wp-block-media-text is-stacked-on-mobile\"><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" width=\"414\" height=\"158\" data-src=\"https:\/\/rothwell.co.th\/wp-content\/uploads\/2025\/07\/8.webp\" alt=\"\" class=\"wp-image-6582 size-full lazyload\" data-srcset=\"https:\/\/rothwell.co.th\/wp-content\/uploads\/2025\/07\/8.webp 414w, https:\/\/rothwell.co.th\/wp-content\/uploads\/2025\/07\/8-300x114.webp 300w\" data-sizes=\"(max-width: 414px) 100vw, 414px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 414px; --smush-placeholder-aspect-ratio: 414\/158;\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p><strong>Color Screen<\/strong><\/p>\n\n\n\n<p>Real-time and clearer display of various values and appointment timing function<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-media-text is-stacked-on-mobile is-vertically-aligned-center\" style=\"grid-template-columns:36% auto\"><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" width=\"244\" height=\"222\" data-src=\"https:\/\/rothwell.co.th\/wp-content\/uploads\/2025\/07\/1.webp\" alt=\"\" class=\"wp-image-6584 size-full lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 244px; --smush-placeholder-aspect-ratio: 244\/222;\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p><strong>Foot Switch<\/strong><\/p>\n\n\n\n<p>Adjust front window height by foot during experiment, to avoid airflow turbulence caused by arm movement.<\/p>\n<\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-media-text is-stacked-on-mobile\" style=\"grid-template-columns:34% auto\"><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" width=\"244\" height=\"222\" data-src=\"https:\/\/rothwell.co.th\/wp-content\/uploads\/2025\/07\/2.webp\" alt=\"\" class=\"wp-image-6585 size-full lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 244px; --smush-placeholder-aspect-ratio: 244\/222;\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p><strong>Work Zone<\/strong><\/p>\n\n\n\n<p>Work zone, made of 304 stainless steel, is surrounded by negative pressure.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-media-text is-stacked-on-mobile\" style=\"grid-template-columns:33% auto\"><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" width=\"244\" height=\"222\" data-src=\"https:\/\/rothwell.co.th\/wp-content\/uploads\/2025\/07\/3.webp\" alt=\"\" class=\"wp-image-6586 size-full lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 244px; --smush-placeholder-aspect-ratio: 244\/222;\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p><strong>Front Window<\/strong><\/p>\n\n\n\n<p>Motorized, Two-layer laminated toughened glass 26mm, Anti UV.<\/p>\n<\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-media-text is-stacked-on-mobile\" style=\"grid-template-columns:41% auto\"><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" width=\"244\" height=\"222\" data-src=\"https:\/\/rothwell.co.th\/wp-content\/uploads\/2025\/07\/4.webp\" alt=\"\" class=\"wp-image-6587 size-full lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 244px; --smush-placeholder-aspect-ratio: 244\/222;\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p><strong>Footmaster Caster<\/strong><\/p>\n\n\n\n<p>Universal caster with brake and leveling feet.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-media-text is-stacked-on-mobile\" style=\"grid-template-columns:33% auto\"><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" width=\"244\" height=\"222\" data-src=\"https:\/\/rothwell.co.th\/wp-content\/uploads\/2025\/07\/5.webp\" alt=\"\" class=\"wp-image-6588 size-full lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 244px; --smush-placeholder-aspect-ratio: 244\/222;\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p><strong>Cabinet Support Block<\/strong><\/p>\n\n\n\n<p>Easy to lift, prevent hand pressing.<\/p>\n<\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-media-text is-stacked-on-mobile\" style=\"grid-template-columns:41% auto\"><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" width=\"244\" height=\"222\" data-src=\"https:\/\/rothwell.co.th\/wp-content\/uploads\/2025\/07\/6.webp\" alt=\"\" class=\"wp-image-6589 size-full lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 244px; --smush-placeholder-aspect-ratio: 244\/222;\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p><strong>Iron hook support<\/strong><\/p>\n\n\n\n<p>rod for panel suppor<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-media-text is-stacked-on-mobile\" style=\"grid-template-columns:33% auto\"><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" width=\"244\" height=\"222\" data-src=\"https:\/\/rothwell.co.th\/wp-content\/uploads\/2025\/07\/7.webp\" alt=\"\" class=\"wp-image-6590 size-full lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 244px; --smush-placeholder-aspect-ratio: 244\/222;\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p><strong>UV LAMP<\/strong><\/p>\n\n\n\n<p>Emission of 253.7 nano meters for most  efficient decontamination                                 <\/p>\n<\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-media-text is-stacked-on-mobile\" style=\"grid-template-columns:41% auto\"><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" width=\"144\" height=\"132\" data-src=\"https:\/\/rothwell.co.th\/wp-content\/uploads\/2025\/07\/9.webp\" alt=\"\" class=\"wp-image-6591 size-full lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 144px; --smush-placeholder-aspect-ratio: 144\/132;\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p><strong>Remote Control<\/strong><\/p>\n\n\n\n<p>All functions can be realized with it, making the operation much easier and more convenient.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>AC Series Class II A2 Biological Safety Cabinet Model:BSC-11<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"categories":[63,64],"tags":[],"class_list":["post-6458","page","type-page","status-publish","hentry","category-biological-safety-cabinet","category-mf"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>AC Series Class II A2 Biological Safety Cabinet - rothwell.co.th<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/rothwell.co.th\/index.php\/ac-series-class-ii-a2-biological-safety-cabinet\/\" \/>\n<meta property=\"og:locale\" content=\"th_TH\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"AC Series Class II A2 Biological Safety Cabinet - rothwell.co.th\" \/>\n<meta property=\"og:description\" content=\"AC Series Class II A2 Biological Safety Cabinet Model:BSC-11\" \/>\n<meta property=\"og:url\" content=\"https:\/\/rothwell.co.th\/index.php\/ac-series-class-ii-a2-biological-safety-cabinet\/\" \/>\n<meta property=\"og:site_name\" content=\"rothwell.co.th\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-18T21:59:04+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/rothwell.co.th\/wp-content\/uploads\/2025\/07\/bsc-1100-ii-a2-x-main-copy.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"287\" \/>\n\t<meta property=\"og:image:height\" content=\"477\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"11 \u0e19\u0e32\u0e17\u0e35\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/rothwell.co.th\\\/index.php\\\/ac-series-class-ii-a2-biological-safety-cabinet\\\/\",\"url\":\"https:\\\/\\\/rothwell.co.th\\\/index.php\\\/ac-series-class-ii-a2-biological-safety-cabinet\\\/\",\"name\":\"AC Series Class II A2 Biological Safety Cabinet - rothwell.co.th\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/rothwell.co.th\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/rothwell.co.th\\\/index.php\\\/ac-series-class-ii-a2-biological-safety-cabinet\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/rothwell.co.th\\\/index.php\\\/ac-series-class-ii-a2-biological-safety-cabinet\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/rothwell.co.th\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/bsc-1100-ii-a2-x-main-copy.webp\",\"datePublished\":\"2025-07-18T19:32:35+00:00\",\"dateModified\":\"2025-07-18T21:59:04+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/rothwell.co.th\\\/index.php\\\/ac-series-class-ii-a2-biological-safety-cabinet\\\/#breadcrumb\"},\"inLanguage\":\"th\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/rothwell.co.th\\\/index.php\\\/ac-series-class-ii-a2-biological-safety-cabinet\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"th\",\"@id\":\"https:\\\/\\\/rothwell.co.th\\\/index.php\\\/ac-series-class-ii-a2-biological-safety-cabinet\\\/#primaryimage\",\"url\":\"https:\\\/\\\/rothwell.co.th\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/bsc-1100-ii-a2-x-main-copy.webp\",\"contentUrl\":\"https:\\\/\\\/rothwell.co.th\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/bsc-1100-ii-a2-x-main-copy.webp\",\"width\":287,\"height\":477,\"caption\":\"AC Series Class II A2 Biological Safety Cabinet\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/rothwell.co.th\\\/index.php\\\/ac-series-class-ii-a2-biological-safety-cabinet\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/rothwell.co.th\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"AC Series Class II A2 Biological Safety Cabinet\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/rothwell.co.th\\\/#website\",\"url\":\"https:\\\/\\\/rothwell.co.th\\\/\",\"name\":\"rothwell.co.th\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/rothwell.co.th\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/rothwell.co.th\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"th\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/rothwell.co.th\\\/#organization\",\"name\":\"rothwell.co.th\",\"url\":\"https:\\\/\\\/rothwell.co.th\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"th\",\"@id\":\"https:\\\/\\\/rothwell.co.th\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/rothwell.co.th\\\/wp-content\\\/uploads\\\/2023\\\/03\\\/cropped-logopng-01.png\",\"contentUrl\":\"https:\\\/\\\/rothwell.co.th\\\/wp-content\\\/uploads\\\/2023\\\/03\\\/cropped-logopng-01.png\",\"width\":250,\"height\":70,\"caption\":\"rothwell.co.th\"},\"image\":{\"@id\":\"https:\\\/\\\/rothwell.co.th\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"AC Series Class II A2 Biological Safety Cabinet - rothwell.co.th","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/rothwell.co.th\/index.php\/ac-series-class-ii-a2-biological-safety-cabinet\/","og_locale":"th_TH","og_type":"article","og_title":"AC Series Class II A2 Biological Safety Cabinet - rothwell.co.th","og_description":"AC Series Class II A2 Biological Safety Cabinet Model:BSC-11","og_url":"https:\/\/rothwell.co.th\/index.php\/ac-series-class-ii-a2-biological-safety-cabinet\/","og_site_name":"rothwell.co.th","article_modified_time":"2025-07-18T21:59:04+00:00","og_image":[{"width":287,"height":477,"url":"https:\/\/rothwell.co.th\/wp-content\/uploads\/2025\/07\/bsc-1100-ii-a2-x-main-copy.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"11 \u0e19\u0e32\u0e17\u0e35"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/rothwell.co.th\/index.php\/ac-series-class-ii-a2-biological-safety-cabinet\/","url":"https:\/\/rothwell.co.th\/index.php\/ac-series-class-ii-a2-biological-safety-cabinet\/","name":"AC Series Class II A2 Biological Safety Cabinet - rothwell.co.th","isPartOf":{"@id":"https:\/\/rothwell.co.th\/#website"},"primaryImageOfPage":{"@id":"https:\/\/rothwell.co.th\/index.php\/ac-series-class-ii-a2-biological-safety-cabinet\/#primaryimage"},"image":{"@id":"https:\/\/rothwell.co.th\/index.php\/ac-series-class-ii-a2-biological-safety-cabinet\/#primaryimage"},"thumbnailUrl":"https:\/\/rothwell.co.th\/wp-content\/uploads\/2025\/07\/bsc-1100-ii-a2-x-main-copy.webp","datePublished":"2025-07-18T19:32:35+00:00","dateModified":"2025-07-18T21:59:04+00:00","breadcrumb":{"@id":"https:\/\/rothwell.co.th\/index.php\/ac-series-class-ii-a2-biological-safety-cabinet\/#breadcrumb"},"inLanguage":"th","potentialAction":[{"@type":"ReadAction","target":["https:\/\/rothwell.co.th\/index.php\/ac-series-class-ii-a2-biological-safety-cabinet\/"]}]},{"@type":"ImageObject","inLanguage":"th","@id":"https:\/\/rothwell.co.th\/index.php\/ac-series-class-ii-a2-biological-safety-cabinet\/#primaryimage","url":"https:\/\/rothwell.co.th\/wp-content\/uploads\/2025\/07\/bsc-1100-ii-a2-x-main-copy.webp","contentUrl":"https:\/\/rothwell.co.th\/wp-content\/uploads\/2025\/07\/bsc-1100-ii-a2-x-main-copy.webp","width":287,"height":477,"caption":"AC Series Class II A2 Biological Safety Cabinet"},{"@type":"BreadcrumbList","@id":"https:\/\/rothwell.co.th\/index.php\/ac-series-class-ii-a2-biological-safety-cabinet\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/rothwell.co.th\/"},{"@type":"ListItem","position":2,"name":"AC Series Class II A2 Biological Safety Cabinet"}]},{"@type":"WebSite","@id":"https:\/\/rothwell.co.th\/#website","url":"https:\/\/rothwell.co.th\/","name":"rothwell.co.th","description":"","publisher":{"@id":"https:\/\/rothwell.co.th\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/rothwell.co.th\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"th"},{"@type":"Organization","@id":"https:\/\/rothwell.co.th\/#organization","name":"rothwell.co.th","url":"https:\/\/rothwell.co.th\/","logo":{"@type":"ImageObject","inLanguage":"th","@id":"https:\/\/rothwell.co.th\/#\/schema\/logo\/image\/","url":"https:\/\/rothwell.co.th\/wp-content\/uploads\/2023\/03\/cropped-logopng-01.png","contentUrl":"https:\/\/rothwell.co.th\/wp-content\/uploads\/2023\/03\/cropped-logopng-01.png","width":250,"height":70,"caption":"rothwell.co.th"},"image":{"@id":"https:\/\/rothwell.co.th\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/rothwell.co.th\/index.php\/wp-json\/wp\/v2\/pages\/6458","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/rothwell.co.th\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/rothwell.co.th\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/rothwell.co.th\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/rothwell.co.th\/index.php\/wp-json\/wp\/v2\/comments?post=6458"}],"version-history":[{"count":8,"href":"https:\/\/rothwell.co.th\/index.php\/wp-json\/wp\/v2\/pages\/6458\/revisions"}],"predecessor-version":[{"id":6592,"href":"https:\/\/rothwell.co.th\/index.php\/wp-json\/wp\/v2\/pages\/6458\/revisions\/6592"}],"wp:attachment":[{"href":"https:\/\/rothwell.co.th\/index.php\/wp-json\/wp\/v2\/media?parent=6458"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/rothwell.co.th\/index.php\/wp-json\/wp\/v2\/categories?post=6458"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/rothwell.co.th\/index.php\/wp-json\/wp\/v2\/tags?post=6458"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}